Receive The State On / Off For A Device; Commands Of The Xtender's Auxiliary Relays By Sms - Studer Xcom-SMS User Manual

Communication module
Table of Contents

Advertisement

Studer Innotec SA
Xcom-SMS

7.7.2 Receive the state ON / OFF for a device

This command will send you the state ON / OFF for each type of device in your system. The
returned state indicates the state of the master of a specific product group.
Format:
sys ?
Examples of "sys" commands:
Command
Functioning of the Xcom-SMS
sys ?
Returns the state of the master of each product type in the system
Example of SMS to receive the
state ON / OFF of the different
product types in your system.
7.8
C
OMMANDS OF THE
The auxiliary relays of your Xtenders are normally set by specific programing of the parameters.
With the following command you may control the relays without using parameters, which makes
it easier to use.
By using this command you may remotely control the start-up of additional loads such as a
heating system, an air conditioner or any other device that can be cabled using the auxiliary
relays.
Turning on and off loads from a distance should always be made knowingly and
with the assurance that there is no inherent risk.
In a system with several appliances of the same kind, all relays with the same index
(AUX 1, AUX 2) are controlled at the same time.
Format:
relay <num>=<state>
<num>
Mandatory
Index of the relay to control, 2 possible values:
1:
2:
<state>
Mandatory
State of the relay, 4 possible values:
off:
on:
auto: automatic
inv:
34
X
'
TENDER
S AUXILIARY RELAYS BY
auxiliary relay 1
auxiliary relay 2
deactivated
activated
automatic reversed
123456 sys ?
Xcom-SMS
- cmd sys: xt=on vt=off
vs=on
V 1.0.0
SMS
User manual