Danger Areas; Reference To Special Dangers - Presto Conti Compact Series Operating And Maintenance Instructions Manual

Channel-type baling press
Table of Contents

Advertisement

PRESTO
GmbH & Co. KG
Bad Laer
These are:
• Failure of light barriers,
• Emergency-off switches and protective
devices
• • Damaging of electrical equipment and
lines as well as insulators.
In case of doubt immediately stop the
unit!

3.6.2. Danger areas

The danger area of the machine is limited to
the horizontal distance measurement of 1 m
to the external dimensions of the channel-
type baling press.
Schematic
view

3.6.3. Reference to special dangers

Electrical energy
The machine will be supplied ready for
operation.
The power connection has to be provided at
the side, doing this the electrical safety
instructions, the regulations and the
Funnel
04/2012 3 - 9
electrical information in the chapter
"Electrical unit"
Attention!
The rotational direction of the electric
motor of the hydraulic pump has to be
strictly observed. A short time wrong
running destroys the hydraulic pump.
The motor is running correctly when the
ventilator wheel at the electric motor rotates
in the direction of the arrow at the housing
indicating the rotational direction and the
compressing die makes a movement
within 5 seconds.
If the compressing die does not make any
movement within this time turn off motor
immediately and change two phases of the
feed line by an electrical expert.
As the pump runs without oil flow in case of
a wrong rotational direction, the motor may
be turned on for a very short time only (5
seconds as a maximum).
Before working on electrical units or systems
these have to be switched dead.
The five safety rules before starting work:
• Switch off
• Secure against reclosure (switch off main
switch and lock)
• Ensure dead circuit
• Grounding
• Cover or screen of adjacent live parts