10.9 SIMOTION P overall reset
● Data that was saved with the _savePersistentMemoryData(), _saveUnitDataSet(),
_exportUnitDataSet() commands and with RAM to ROM.
If the retain data is backed up (with _savePersistentMemoryData()), this data is backed up
again to the non-volatile data after the general reset. Thus, the user can perform a general
reset to force the saved retain data to be restored.
● Licenses
The technology packages and user data (configuration data, programs, parameter
assignments) previously backed up to an external CFast card by means of the Copy RAM to
ROM menu command are transferred to the volatile data area of the SIMOTION P320‑4 after
the general reset.
Thus, an existing configuration on the external CFast card is loaded to the SIMOTION device
following the general reset.
Further information
Data storage concept overview (Page 157)
10.9.2

Overall reset using the mode selector (on screen)

For SIMOTION P320-4, the overall reset using a simulated mode selector is performed using
the SIMOTION P State application.
Note
MRES mode switch position
If you set MRES via the SIMOTION P State application, the SIMOTION P320-4 automatically
goes into the STOP operating state.