Commissioning (software)
10.8 Data storage concept
Note
SIMOTION IT
You can find further information about SIMOTION IT in the following documentation:
● SIMOTION IT Diagnostics and Configuration Diagnostics Manual
● SIMOTION IT Programming and Web Services Programming Manual
● SIMOTION IT Virtual Machine and Servlets Programming Manual
10.8.3.5
Backing up and restoring project data (file structure)
The project data (file structure) is located in the USER directory on the external CFast card
(drive D) of the SIMOTION P320-4.
1. To save the project data, copy the USER directory from the external CFast card, e.g. to a
storage medium of the SIMOTION P320-4 or to a USB flash drive.
2. To restore the project data, copy the USER directory, e.g. from a storage medium of the
SIMOTION P320-4 or a USB flash drive, to the external CFast card and replace the existing
directory.
This also enables series commissioning without a programming device or SIMOTION SCOUT.
Figure 10-6
Backing up and restoring a file system
Sequence of a series commissioning
Copy the USER directory from a storage medium to the external CFast card (Drive D) of the
SIMOTION P320-4 to be newly commissioned.
SIMOTION P320-4 must be in the terminated state for this.
164
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 11/2016