Service and maintenance
11.5 Special power-up situations
SRAM image (storage medium) or SRAM backup (storage medium) is OK, if:
● The SIMOTION software release of the SRAM image/backup matches the installed
software release.
● Windows has been shut down properly (the POWER FAIL mechanism of SIMOTION P
does not suffice here).
● The checksum test on the SRAM image/backup was successful.
● The battery status was good when the SRAM image was backed up.
Table 11-2
SRAM
"OK"?
Yes
No
No
No
The user data backed up in the SRAM of the SIMOTION P320‑4 is used.
1)
The user data backed up in the SRAM image on the storage medium of the SIMOTION P320‑4 is
2)
used.
The user data backed up in the SRAM backup on the storage medium of the SIMOTION P320‑4 is
3)
used.
If the serial number of the SIMOTION P320‑4 is not known:
The serial number of the SIMOTION P320‑4 does not correspond to the one that was last
saved on the SIMOTION P320‑4, for example, after the replacement of the SIMOTION P320‑4.
SRAM image (storage medium) or SRAM backup (storage medium) is OK, if:
● The SIMOTION software release of the SRAM image/backup matches the installed
software release.
● Windows has been shut down properly (the POWER FAIL mechanism of SIMOTION P
does not suffice here).
● The checksum test on the SRAM image/backup was successful.
● The battery status was good when the SRAM image was backed up.
Table 11-3
SRAM
"OK"?
Yes
Yes
Yes
No
190
SRAM handling if the serial number is known
SRAM image
SRAM backup
(storage medium)
(storage medium)
"OK"?
"OK"?
Not applicable
Not applicable
Yes
Not applicable
No
Yes
No
No
SRAM handling if the serial number is unknown
SRAM image
SRAM backup
(storage medium)
(storage medium)
"OK"?
"OK"?
Yes
Not applicable
No
Yes
No
No
Yes
Not applicable
User data
used
Board
1)
IMAGE
2)
BACKUP
3)
Overall reset
User data
used
Board
or IMAGE
1)
Board
or BACK‐
1)
UP
3)
Board
1)
IMAGE
2)
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 11/2016
Note
Normal statup
No message box or
alarms
No message box or
alarms
Required
Note
Query made
2)
Query made
No message box
No message box