1. Remove the cable tie A.
2. Remove the contact disc cables B from the Mover PCB,
using a terminal screwdriver. Note brown cable top and
blue cable bottom.
Feed the cables through the chassis plate.
3. Carefully separate and remove the complete contact
disc C from the suspension base D by releasing the
self-adhesive tape.
4. Remove, clean off the remains of the self adhesive tape.
1586747-C
5. Fit the new self adhesive tape E and the new contact
disc C.
6. Feed the cables B through the chassis plate and
connect them to the Mover PCB.
7. Re-assemble the hoist and reset the emergency stop.