15.5.38 Original jam access cover opening/closing sensor (SR13)

(1)
Open the original jam access cover.
(2)
Remove 4 screws and take off the sensor
bracket.
(3)
Disconnect 1 connector. Release 2 latches
and take off the original jam access cover
opening/closing sensor.

15.5.39 Feeder lower guide unit

(1)
Take off the original tray.
P.15-18 "15.5.6 Original tray"
(2)
Take off the guide.