Notes:
Be sure to install the lamp harness by
following the procedure below.
1. Using alcohol, clean the area where the
seal is to be attached.
2. Align the black line on the lamp harness
with the position as shown in the figure,
and fix it with a seal.
3. Align the bent portion of the lamp harness
with the position as shown in the figure,
and fix it with a clamp.
4. Attach 3 seals to each position of the
punched mark and fix the lamp harness.
5. After the installation, move carriage-1
towards the left and confirm that there is
no abnormality in the lamp harness, such
as twisting.
(5)
Rotate the carriage-1 in the direction shown
in the figure at right, paying attention not to
touch the mirror. Then take out the carriage-
1.
e-STUDIO555/655/755/855
SCANNING SECTION
Lamp harness
Black Line
Stud
Punched mark
Seal
Seal
Clamp
Punched
Lamp
mark
harness
Carriage-1
© 2009 - 2011 TOSHIBA TEC CORPORATION All rights reserved
6 - 20
Lamp harness
Seal
Fig. 6-35
Punched
mark
Punched
mark
Stud
Fig. 6-36