NOTE:
Follow these guidelines when you use the RPS1000-A3 to supply power to the S5800-60C-PWR switch:
You must install the RPS1000-A3 with two power modules. With only one power module, the RPS might
•
enter the over-current protection state and stop supplying power.
•
Ensure that the two lines between the PSR750-D and the RPS1000-A3 are securely connected. Insecure
connection of either line can cause the affected power module to enter the over-current protection state
and stop supplying power to the switch.
You must connect the PSR750-D to the RPS1000-A3 by using the dedicated H3C power cable, and
•
correctly identify the positive (+) and negative (-) marks on the wires.
The RPS1000-A3 has eight outputs, and you can connect the PSR750-D only to OUTPUT1 and
•
OUTPUT2.
Figure 71 Remove the protective cover from the PSR750-D
Figure 72 Connect the PSR750-D to the RPS1000-A3
Connecting the LSVM1AC650/LSVM1AC300
1.
Insert the female connector of the AC power cord supplied with the power module into the
AC-input power receptacle of the power module.
2.
Use a cable tie to secure the power cord to the handle of the power module, as shown in
73.
3.
Connect the other end of the power cord to an AC power outlet.
65
Figure