Mitsubishi MELSEC Q Series Reference Manual page 186

With melsec communication protocol
Hide thumbs Also See for MELSEC Q Series:

Advertisement

(Data name)
External device
side
(Example)
(Data name)
Programmable controller CPU side
(Example)
3 - 126
3 WHEN COMMUNICATING USING THE QnA COMPATIBLE 3E/3C/4C FRAMES OR 4E FRAME
(b) Monitor data is registered in the following ways while communicating in
binary code
1)
Monitor condition
When the value of link register W100 reaches "7B
number 1000 of the program file CONB1.QPG is being executed
2) Device memories to be monitored (read)
• Word access
• Double word access : D1500 to D1501, Y160 to Y17F, M1111 to
Monitor condition not designated
File and step No. designated
Word device value designated
L
H
H
-
-
-
-
L
H
L
H
C
O
N
B
1
01
08
40
00
03
0F
01
00
43
4F
4E
42
31
20
H
H
H
H
H
H
H
H
H
H
H
H
H
0801
H
Number of points to be registered
(Refer to Section 3.3.8.)
L
-
H
L
-
H
(D)
04
03
00
00
00
A8
00
00
00
C2
H
H
H
H
H
H
H
H
H
Devices for the number of word
access points
POINT
Designate the number of access points within the following range.
For bit devices, one word access point is 16 bits and one double word access point
is 32 bits.
For word devices, one word access point is one word and one double word access
point is two words.
(1) When accessing the QCPU on the station where the C24/E71 is loaded (local
station), or the QCPU on the station connected on a Q series supporting
network system (CC-Link IE Controller Network, CC-Link IE Field Network,
MELSECNET/H, MELSECNET/10, or Ethernet) (other station)
Number of access points: 1  (number of word access points +
When registering the file registers (ZR), use the formula, (number of access
points) x 2, for calculation.
For example, to register ZRs of 15 points, the number of access points is
calculated as 30 points.
(Note that the Basic model QCPU is excluded.)
(2) When accessing the QnACPU (other station), or the QCPU/QnACPU on the
station connected on a QnA series supporting network system
(MELSECNET/10, or Ethernet) (other station)
Number of access points: 1  (number of word access points +
(3) When accessing a programmable controller CPU (other station) except (1) and
(2)
Access is disabled.
: D0, T0, M100 to M115, X20 to X2F
M1142
(Refer to Section 3.3.8.)
-
-
L
L
-
H
L
-
-
H
L
H L
H
(1000)
_
_
_
Q
P
G
20
20
51
50
47
20
E8
03
00
00
00
00
00
00
00
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
000003E8
H
(Refer to Section 3.3.1.)
L
-
H
L
-
H
L
-
H
L
-
(100)
(1500)
(T)
(M)
(X)
(D)
64
00
00
90
20
00
00
9C
DC
05
00
A8
60
01
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
Devices for the number of double
word accesses points
number of double word access points) 192
number of double word access points) 96
" (123) while step
H
L
H
L
-
H
L
H
L
H
L
-
H
(123)
00
00
01
00
B4
FF
FF
7B
00
00
00
00
90
00
H
H
H
H
H
H
H
H
H
H
H
H
H
H
Dummy because word
000100
H
device value is designated
L
-
H
H
(1111)
(Y)
(M)
00
9D
57
04
00
90
H
H
H
H
H
H
H
3 - 126

Hide quick links:

Advertisement

loading