Connecting An Analog Ptz Camera; Figure 3-15 4-Pin Adapter - Honeywell MAXPRO NVR Series Hardware Installation And Configuration Manual

5.0
Hide thumbs Also See for MAXPRO NVR Series:
Table of Contents

Advertisement

Connecting an Analog PTZ Camera

Attaching the 4-Pin Adapter
MAXPRO NVR 5.0 Installation and Configuration Guide
Note:
Please refer to the specific Hybrid unit data sheet for more information on number
of sensor inputs supported on a specific unit.
Setting up a PTZ Camera is simple. The NVR Hybrid comes pre-assembled with an internal
PTZ adapter. The cabling may be run up to 4,000 ft using 22 Gauge Twisted Pair. It is
important to understand how the PTZ connects to the NVR. The NVR outputs an RS-232
signal and converts in to an RS-422/485 signal which is then sent to the PTZ camera.
S E T T I N G U P T H E M A X P R O N V R
MAXPRO NVR Hybrid Connections
1.Locate the PTZ adapter cable.
2.Connect the wires of the PTZ adapter to the PTZ
camera. The yellow wire should connect to the RX+ on
the camera and the orange wire should connect to the
RX-.
3.Connect the other end of the adapter to the XVR unit
as shown.
4.Assign the PTZ camera an ID number in PTZ Setup
that coincides with the number assigned to the camera.
This is normally done utilizing a dip-switch configuration
method on the addressable dome. For Example: If the
camera is plugged into input number 5, set the PTZ unit
to ID number 5.
Figure 3-15
4-Pin Adapter