Fusible Link Harness

Testing
Electrical System: Component Testing
1
g288437
1.
Starter motor shield removed)
P02
TO MAIN HARNESS P22
g288438
Your Groundsmaster uses two (2) fusible links for circuit protection. These fusible
links are located in a harness that connects the starter B+ terminal to the wire
harness
(Figure
195). If either of these links should fail, current to the protected
circuits will be interrupted. Refer to
link information.
1. Park machine on a level surface, lower cutting units and stop engine.
Remove key from key switch.
2. Raise hood and turn the battery−disconnect switch to the OFF position.
3. Remove the shield over the starter motor.
4. Locate and unplug fusible link connector from machine wire harness.
5. Use a multimeter to make sure that continuity exists between the fusible
link terminals.
6. If either fusible link is open, replace the fusible link harness.
Note: It is not recommended to replace individual fusible link conductors of
the fusible link harness. If any of the harness links are open (failed), replace
the entire fusible link harness.
2
Figure 194
2.
Fusible link harness
FUSIBLE LINK (14 GAUGE)
FUSIBLE LINK (16 GAUGE)
Figure 195