Toro Electronic Controllers (TECs) (continued)
Groundsmaster
®
5900 & 5910
16227SL Rev B
The slave TEC controls electrical output to the following outputs:
Master TEC Input Number
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
OUT 9
OUT 10
OUT 11
OUT 12
OUT 13
OUT 14
Before performing welding on the machine, turn the
battery−disconnect switch to the OFF position, disconnect the wire
harness connector from the TECs and disconnect the terminal
connector from the 12 Volt alternator. Also, disconnect and remove
the Yanmar ECU. These steps will prevent damage to the machine
electrical system when welding.
Left Wing Deck Raise Solenoid (S2)
Left Wing Deck Lower Solenoid (S3)
Deck Raise/Lower Enable Solenoid (S1)
High/Low Range Traction Speed Solenoid (SV)
Left Wing Deck Float Solenoid (S4)
Right Wing Deck Raise Solenoid (S7)
Right Wing Deck Lower Solenoid (S8)
Right Wing Deck Float Solenoid (S9)
IMPORTANT
Page 6–67
Description
Front Deck Raise Solenoid (S5)
Front Deck Float Solenoid (S6)
Front Deck PTO (PRV)
Left Wing Deck PTO (PRV)
Right Wing Deck PTO (PRV)
Alarm
Electrical System: Component Testing