INPUT/OUTPUT (continued)
Electrical System: InfoCenter Display
g288323
Once the deck is fully lowered, the deck should float and following outputs
should occur
(Figure
160):
•
Hydraulic solenoid valve S9 should be energized (RIGHT DECK FLOAT ON).
Note: If a deck is already fully lowered when the key switch is moved
from OFF to RUN, the deck will not be in float until the deck raise/lower
switch is momentarily pressed to lower.
g288324
To raise the right wing cutting deck, the following inputs and qualifiers are
required
(Figure
161):
•
Operator seat needs to be occupied (SEAT ON).
•
High/Low traction speed range switch in LO position (HIGH RANGE
REQUEST OFF).
•
Hydraulic solenoid valve SV should be de−energized (HIGH RANGE OFF).
•
Right wing deck raise/lower switch pressed to raise (RIGHT DECK RAISE
ON).
If the proper inputs exist, the following outputs should occur
•
Hydraulic solenoid valve S1 should be energized (MASTER LIFT SOLENOID
ON).
•
Hydraulic solenoid valve S7 should be energized (RIGHT DECK RAISE ON).
Figure 160
(Float)
Figure 161
(Raise)
Page 6–28
(Figure
161):
Groundsmaster
®
5900 & 5910
16227SL Rev B