Testing (continued)
Groundsmaster
®
5900 & 5910
16227SL Rev B
g288591
1.
Traction control manifold
C. The coils of the solenoid valves at the following locations are the same.
Resistance of these coils should be approximately 7.25 ohms when
tested at 20 ºC (68 ºF):
Steering/Lift manifold S10
Traction manifold SV
Note: Hydraulic solenoid valve SV (traction manifold) and S10
(steering/lift manifold) do not have replaceable coils. If these solenoid
coils fail a resistance test, replace the entire valve assembly (see
Cartridge Valve Service (page
3. After testing is complete, connect wire harness electrical connector to the
solenoid coil.
1
Figure 250
2.
Solenoid valve SV
(Figure
248).
(Figure
250).
5–158)).