Ed-1E434, Group 200 Cable; Table P. Ed-1E434, Group 200 Cable Connection (Phase 2) - AT&T System 85 Installation And Test

Release 2 versions 1, 2, 3, and 4. remote module and remote group interface
Hide thumbs Also See for System 85:
Table of Contents

Advertisement

ED -1E434, Group 200 Cable
Install the ED -1E434, Group 200 cables (Figure 34) from the RMI carrier backplane(s) to the
backplane of the central module(s) selected to provide the on-line and maintenance signals to
the RMI carrier. Connect the cables from E00, E01, E02, and E03 on the RMI carrier
backplane to the next available electrical port on the designated module control carrier(s)
(Table P).
TABLE P. ED-1E434, Group 200 Cable Connection (Phase 2)
RMI Carrier
Connector
E00
E01*
E02
E03
Module Control
00
01
00
01
Carrier
Electrical
1
E35
E35
E04
E04
Port Number
2
E32
E32
E09
E09
3
E34
E34
E08
E08
4
E37
E37
E13
E13
5
E39
E39
E12
E12
6
E36
E36
E17
E17
7
E38
E38
E16
E16
8
E41
E41
E21
E21
9
E43
E43
E20
E20
10 rE 40 rE 40
E25
E25
11 1E42 \E42
E24
E24
* RMI Carrier Conne&or E 01 and E03 are used
for Duplicated Sysams only.
1,Atc+