ED -1E434, Group 300 Cable
Install the ED -1E434, Group 300 cables (Figure 26) from the common control to the module
control and TMS/RMI cabinets. These cables provide connections to daisy chain the
extended MAAP feature.
The Group 300 cables run from D5 (EXT MAAP) on the common control cabinet to EXT
MAAP I on the module control cabinet or TMS/RMI cabinet connector plate 845416577.
Then another Group 300 cable is run from EXT MAAP 0 on the same connector plate to
EXT MAAP I on the next module control or TMS/RMI cabinet. This process is repeated
until all the module control and TMS/RMI cabinets that require the extended MAAP feature
are connected. After the last cabinet is connected, a ED -1E434, Group 344 terminating plug
is required in connector EXT MAAP 0 of the last connector plate 845416577.
1
.3-- MINIMUM LENGTH 50 FT -El
RJ
L
25-PAIR
SHIELDED
CABLE
55-21997, L1
Figure 26. ED-1E434, Group 300 Cable
,