Group 3 Central Extended MAAP Bracket (Phases 1 and 2)
Install ED-1E469, Group 3 Extended MAAP Bracket (Figure 16) in each Phase 1 central
module control cabinet associated with RMI.
For Phase 2, this bracket is only required when a Phase 2 system is used in combination
with a Phase 1 system. The bracket is placed in the Phase 1 central module control cabinets
that have extended MAAP.
When viewed from the front of the cabinet, this bracket is mounted on the left cabinet
upright as shown in Figure 17 using the hardware provided.
The ED -1E469, Group 3 Extended MAAP Bracket has a circuit pack mounted on the back
that is designated ZAEY2. This bracket and circuit pack connections are described in the
"Central Location Cabling" section.
PL1
E5
E4
E3
E2
El
Et)
PLO
(BELOW P11)
MAAP
CONNECTOR
"ZAEY2"
CIRCUIT
PACK
EXTENDED MAAP BRACKET
E01E469, GROUP 3 (TOP VIEW)
MAAP
CIRCUIT BREAKER
Figure 16. ED-1E469, Group 3 Central Extended MAAP Bracket (Phases 1 and 2)