S Cursor moving keys can also be created automatically when a numeral/char-
Reference:
acter string input field is registered on a screen.
S Input fields can also be designated using the input key – control.
The attributes for the cursor moving keys are as follows.
Settings
Use Window/Keyboard Screen
Screen No.
Local 1
(Keyboard)
Local 2
Window Position
X
Y
Replace Local
Window
Auto Arrange
• Settings and action type of window to be used when using Use Window/Key-
board Screen is same as the input key-window/keyboard function which has
Open action type.
Refer to Window Key Function (page 124).
Window Moving Key Function
This function moves a window by pressing a window moving key, which is pre-
registered on a window, while the PT is running.
Window moving key can be registered on a window screen.
S Window can be moved also by the operation of window control area. (Refer to
Reference:
page 301.)
S Window moving key can be used only on a local window. It does not function if
the window screen is displayed as a global window.
Window moving key has no special attributes.
Moving a Window By The Operation of a Window Moving Key
To move a window by the operation of a window moving key, follow the proce-
dure below.
1, 2, 3...
1. Pre-register a window moving key on the window to be moved.
2. Press the window moving key on a window to be moved while the PT is run-
ning.
Open window/keyboard?
Check mark (open)/No check mark (do not open)
Screen number of the window/keyboard to be opened
(setting effective only if a check mark is set for Local 1
(Keyboard) of Use Window/Keyboard Screen)
1 to 3999
Screen number of the window to be opened (setting
effective only if a check mark is set for Local 2 of Use
Window/Keyboard Screen)
1 to 3999
X coordinate of bottom-left corner (multiple of 20)
NT31/NT31C: 0 to 300
NT631/NT631C: 0 to 620
Y coordinate of bottom-left corner (multiple of 20 - 1)
NT31/NT31C: 19 to 239
NT631/NT631C: 19 to 479
Designate the behavior when other window of the
specified type (local window 1/local window 2) is already
opened
Check mark (replace)/No check mark (do not replace)
Move together with the input field associated in editing at
the Support Tool?
Check mark (yes)/No check mark (no)