■ Input and output signal flow (Float mode)
Converter Rec Level adjusts the recording levels of each input,
and Tr1-6 Fader adjusts the levels of each input sent to the
LR track. Both types of levels can be adjusted with . The
behavior of the Rec Level and Tr1-6 Fader when is
operated can be set to one of the following two options
usingMenu > INPUT > Track Knob.
■ Reference Level (default)
Operating when recording is stopped adjusts the Rec
Level . When recording starts, the Rec Level becomes fixed at
the levels set at the time recording started. During recording,
adjust the Tr1-6 Faders .
■ Rec Level
always adjust the Rec Level both during recording and
when recording is stopped.The Tr1-6 Faders are bypassed.
The Input Limiter is disabled when in Dual mode.
191