Siemens SIMATIC IPC847D Operating Instructions Manual page 147

Hide thumbs Also See for SIMATIC IPC847D:
Table of Contents

Advertisement

External Reset, X5, Type JST B2B-PH-SM3-TB
Pin no.
1
2
External Power button, X529, Type JST B2B-PH-SM3-TB
Pin no.
1
2
Pin assignment of the internal USB 2.0 interface connector, X535, X536
Pin no.
1
2
3
4
5
6
7
8
9
10
Pin assignment of the internal USB3/USB2 interface connector, X502
Pin no.
USB3 (USB3/USB 2.0 contacts)
A1
A2
A3
A4
A5
A6
A7
A8
A9
SIMATIC IPC847D
Operating Instructions, 01/2014, A5E32997454-AA
Short name
Meaning
GND
Ground
Reset
0 V level means reset
Short name
Meaning
EXT_PWRBTN
OV level means Power button
pressed
GND
Ground
Short name
Meaning
VCC
+ 5 V (fused)
VCC
+ 5 V (fused)
-Data USB1
Data channel
-Data USB3
Data channel
+Data USB1
Data channel
+Data USB3
Data channel
GND
Ground
GND
Ground
GND
Ground
Key
Short name
Meaning
VCC
+ 5 V (fused)
SSRX-
Data channel USB3
SSRX+
Data channel USB3
GND
Ground
SSTX-
Data channel USB3
SSTX+
Data channel USB3
GND
Ground
-Data
Data channel USB2
+Data
Data channel USB2
Technical specifications
8.5 Hardware description
Input / output
-
Input
Input / output
Input
-
Input / output
Output
Output
Input / output
Input / output
Input / output
Input / output
-
Input / output
Output
Input
Input
-
Output
Output
Input / output
Input / output
147