1B-12 AIR CONDITIONING (OPTIONAL)
1. Plastic hammer
2. Pipe
4) Align keyway of armature plate with keyway of shaft.
5) Drive in armature plate by using a pipe whose inner diameter
is 8.5 mm (0.335 in.) or more and outer diameter is 19 mm
(0.748 in.) or less.
Diameter "a": 8.5 mm (0.335 in.) or more
Diameter "b": 19 mm (0.748 in.) or less
6) Adjust clearance, between armature plate and magnet clutch
by putting shim on compressor shaft.
Standard clearance "c" : 0.4 – 0.8 mm (0.016 – 0.031 in.)
7) Tighten new armature plate nut as specified below.
Tightening Torque
(a): 17 – 19 N·m (1.7 – 1.9 kg-m, 12.3 – 13.7 Ib-ft)
Special Tool
(A): 09920-55810
8) Place lead wire under lead wire clamp, and tighten lead wire
clamp screw.
Tightening Torque
(b): 2.5 – 3.0 N·m (0.25 – 0.3 kg-m, 1.8 – 2.2 Ib-ft)