Invacare Storm4 Series Service Manual page 7

Hide thumbs Also See for Storm4 Series:
Table of Contents

Advertisement

CAUTION!
Injury hazard and risk of damage to mobility device due to improper or incomplete maintenance work
– Use only undamaged tools in good condition.
– Some moving parts are mounted in sockets with PTFE coating (Teflon™). Never grease these sockets!
– Never use "normal" nuts instead of self-locking nuts.
– Always use correctly-dimensioned washers and spacers.
– When reassembling, always replace any cable ties which were cut during dismantling.
– After completing your work / before renewed start-up of the mobility device, check all connections for
tight fitting.
– After completing your work / before renewed start-up of the mobility device, check all parts for correct locking.
– Only operate the mobility device with the approved tyre pressures (see technical data).
– Check all electrical components for correct function. Note that incorrect polarity can result in damage
to the control system.
– Always carry out a trial run at the end of your work.
CAUTION!
Risk of injury and damage to property, if the maximum speed reduction on a wheelchair with a lifter does
not function correctly
The wheelchair's control unit must reduce the maximum possible speed as soon as the lifter is raised.
– Test the maximum speed reduction for correct function after any maintenance work or modifications to the
wheelchair.
CAUTION!
Any changes to the drive program can affect the driving characteristics and the tipping stability of the
mobility device
– Changes to the drive program may only be carried out by trained Invacare providers.
– Invacare supplies all mobility devices with a standard drive program ex-works. Invacare can only give a
warranty for safe mobility device driving behavior - especially tipping stability - for this standard drive program.
Mark all current settings for the mobility device (seat, armrests, backrest etc.), and the associated cable connecting
plugs, before dismantling. This makes reassembly easier. All plugs are fitted with mechanical locks which prevent
release of the connecting plugs during operation. To release the connecting plugs the safety locks must be pressed
in. When reassembling ensure that these safety locks are correctly engaged.
1555830-C
Safety
7

Advertisement

Table of Contents
loading

Table of Contents