Venting Introduction; Venting Arrangement For Horizontal Terminations - Regency City ACB60ENG Owners & Installation Manual

Direct vent
Table of Contents

Advertisement

Venting Introduction

The ACB60E uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside
combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or
gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

Venting Arrangement for Horizontal Terminations

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90
Note: Must use optional rigid pipe adapter (Part# 770-994) when using Rigid Pipe Venting Systems)
5.5
5.2
4.9
4.2
3.6
3.
2.4
1.8
1.2
0.6
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 0.
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required.
Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous
vent length of up to 3 meters. If longer runs are required, rigid pipe must be used.
Maintain clearances to combustibles as listed in "Clearances" section
Horizontal vent must be supported every 0.91 meters.
Firestops are required at each floor level and whenever passing through a wall.
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
2
0.6
0.9
Vent Restrictor
on Set 2
1
1478 mm
Horizontal (Meters)
4
3
*Unit is not exactly as shown.
installation
o
(two 45
o
elbows equal one 90
5
6
City Series ACB60E | 55
o
elbow).

Advertisement

Table of Contents
loading