3. Program examples
Advanced unit is installed on a master backplane together with a slave unit. Access the memory in the
advanced unit from the CPU on its master station.
The program is based on the configuration shown below.
In the example above, the control data (32-bit configuration) which is supplied for "Memory access
instructions (F152 and F153)" can be expressed as follows.
Note:
For example, when connecting the data (S1) to "Data register DT0", store the data (S1+1) in "Data
register DT1".
Specify header address DT0 only for the memory access instruction.