Range Reference Table

The range reference tables are given below.
7.4.1
Address (Decimal)
CH1
CH2
CH3
CH4
CH5
190
198
206
214
222
191
199
207
215
223
192
200
208
216
224
193
201
209
217
225
194
202
210
218
226
195
203
211
219
227
196
204
212
220
228
197
205
213
221
229
(1) Compare the factory default offset value with the reference value F868
(2) Compare the factory default gain value with the reference value 3640
(3) Compare the user range settings offset value with the value obtained
(4) Compare the user range settings gain value with the value obtained from
(5) Make sure to obtain the chart of standard thermal electromotive force,
(6) Make sure to obtain the chart of standard thermal electromotive force,
(Example)
Set
Value type
temperature
Offset value
- 200.0
Gain value
900.0
7
- 33
7.4 Range Reference Table

7.4.1 Range reference table (Q68TD-G-H02)

Range reference table (Q68TD-G-H02)
CH6
CH7
CH8
230
238
246
Factory default offset value
231
239
247
Factory default gain value
232
240
248
User range settings offset value
233
241
249
User range settings gain value
234
242
250
User range settings thermal EMF offset value
235
243
251
User range settings thermal EMF offset value
236
244
252
User range settings thermal EMF gain value
237
245
253
User range settings thermal EMF gain value
from the following expression.
User range settings thermal
(Digital value) =
EMF offset value ( V)
the following expression.
User range settings thermal
(Digital value) =
EMF gain value ( V)
complying with JIS C 1602-1995 and IEC584-1, IEC584-2 for the user
range settings offset thermal electromotive force value.Then, compare
the value with the user-set offset setting temperature.
complying with JIS C 1602-1995 and IEC584-1, IEC584-2 for the user
range settings gain thermal electromotive force value.Then, compare the
value with the user-set gain setting temperature.
When offset/gain setting is made at the offset set temperature of -200.0°C and the gain
set temperature of 900.0°C with an E type thermocouple connected
Reference value of user range settings thermal
EMF offset/gain value
- 8825( V)
68787( V)
Description
Digital value for offset value set prior to
shipment (Reference value F868
Digital value for gain value set prior to
shipment (Reference value 3640
Digital value for user-set offset value (Refer to
(3))
Digital value for user-set gain value (Refer to
(4))
(L)
Thermal EMF for user-set offset set
(H)
temperature ( V unit) (Refer to (5))
(L)
Thermal EMF for user-set gain set temperature
( V unit) (Refer to (6))
(H)
Reference value of user range settings offset/
- 8825
15832
68787
15832
Reference value
)
H
)
H
15832
45000
185
15832
45000
185
gain value
45000-185 =F326
H
45000-185 = 5DD0
H
.
H
.
H

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1d5c-qtiu-eQ68td-g-h01Q68td-g-h02

Table of Contents