Troubleshooting
Operating Instructions 867 - 04.0 - 03/2018
Error/
Code
Possible cause
warning
3105
Error
U24 V short circuit
3106
Error
U24 V (I
3107
Error
Pedal not connected
3109
Warning
Operation lock
3151
Warning
Maintenance necessary
(operation cannot
continue unless
parameter t 51 14 is
reset)
6353
Error
Internal EEprom
communication error
6354
Error
External EEprom
communication error
8401
Error
Watchdog
Remedial action
• Disconnect 37-pin plug
• Replace control if error
is not corrected
• Test inputs/outputs for
24 V short circuit
2
• One or several
T) overload
magnets defective
• Connect analog pedal
• Check tilt sensor on
machine
• Service is urgently
required  Service
Instructions
• Switch off the control
• Wait until the LEDs are
off
• Switch the machine
back on
• Switch off the control
• Wait until the LEDs are
off
• Check machine ID
connection
• Switch the control back
on
• Software update
• Machine ID reset
• Replace the control