DURKOPP ADLER 867 Durkopp Adler page 145

Hide thumbs Also See for 867:
Table of Contents

Advertisement

Troubleshooting
Operating Instructions 867 - 04.0 - 03/2018
Error/
Code
Possible cause
warning
1007
Error
Error in the reference run • Replace the encoder
1008
Error
Encoder error
1010
Error
External synchronizer
plug (Sub-D, 9-pin) not
connected
1011
Error
Encoder Z pulse missing • Switch off the control,
1012
Error
Synchronizer fault
1052
Error
Sewing motor
overcurrent, internal
current increase >25 A
1053
Error
Sewing motor
overvoltage
1054
Error
Internal short circuit
1055
Error
Sewing motor overload
Remedial action
• Eliminate stiff
movement in the
sewing machine
• Replace the encoder
• Connect cable of
external synchronizer
to control; use correct
connection (Sync)
• Only required for
machines with
transmission!
adjust the handwheel,
and switch the control
on again
• If error is not corrected,
check encoder
• Replace the
synchronizer
• Check selection of
class
• Replace the control
• Replace sewing motor
• Replace the encoder
• Check selection of
class
• Replace the control
• Replace the control
• Eliminate stiff
movement in the
sewing machine
• Replace the encoder
• Replace sewing motor
143