Event code
Event name
24400000 hex
Unit Status,
Antenna
Error
34980000 hex
Results Infor-
mation, Data
Storage Area
Specification
Error
54A00000 hex
Results Infor-
mation, ID
Tag Address
Error
54A10000 hex
Results Infor-
mation, Write
Protection
Error
54A20000 hex
Results Infor-
mation, Com-
mand Error
648C0000 hex
Unit Status,
Command
Error End
648D0000 hex
Results Infor-
mation, Veri-
fication Error
648E 0000 hex
Results Infor-
mation, ID
Tag Commu-
nications
Error
648F 0000 hex
Results Infor-
mation, ID
Tag Missing
Error
64900000 hex
Results Infor-
mation, ID
System Error
1
NJ-series Troubleshooting Manual (W503)
Meaning
Assumed cause
An error occurred in
• The setting of the Connected
the Antenna.
Antenna Setting (device vari-
able *_Ch#_AntConn) does not
agree with the Antenna that is
connected.
• The V680-H01 or V680-H01-V2
was connected to the CJ1W-
V680C12.
The data storage
• The user program specifies
area specification is
addresses in the DM, CIO, AR,
not correct.
EM, or other areas that exceed
the ranges defined for the data
storage area specifications.
The address of the
• The address of an ID Tag spec-
ID Tag is wrong.
ified in a command is incorrect.
An attempt was
• The specified address or num-
made to write to a
ber of bytes is incorrect.
write-protected
• Write-protection is enabled for
area of the ID Tag.
the area you attempted to write
to in the ID Tag.
The command to
• The contents of the following
the ID Sensor Unit
external device variables is not
is not correct.
data that can be specified
(where # is the channel num-
ber).
*_Ch#_CmdSet
*_Ch#_ProcAdr
*_Ch#_ProcByte
*_Ch#_CmdOption
"#" in the variable name is the
Antenna (Head) number.
A processing error
• A processing error occurred.
occurred.
The correct data
• The travel speed of the ID Tag
could not be writ-
is outside the specified range.
ten to the ID Tag.
• The distance between the
Antenna and ID Tag is outside
the specified range.
• Noise
An error occurred in
• The travel speed of the ID Tag
communications
is outside the specified range.
with an ID Tag, pre-
• The distance between the
venting a normal
Antenna and ID Tag is outside
end.
the specified range.
• Noise
There is no ID Tag
• The communications specifica-
in the communica-
tion is set to trigger, and the ID
tions area.
Tag is not in the communica-
tions area when the trigger
occurs.
• The communications specifica-
tion is set to single auto or
repeat auto, and the wait time
reached the Auto Wait Time.
• An Amplifier is connected, but
an Antenna is not connected.
ID system error 1
• System error 1 occurred.
occurred.
3 Error Tables
Level
Maj
Prt
Min
Obs
Info
S
CJ-series ID
Sensor Units
Operation
Manual for NJ-
series CPU
Unit (Cat. No.
Z317)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
Reference