Omron NJ Series Troubleshooting Manual page 186

Sysmac machine automation controller
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

3 Error Tables
Event code
Event name
48020000 hex
System Error
58210000 hex
Output Con-
trol Timeout
for Parallel
I/O, PLC
Link, or Eth-
erNet/IP
58220000 hex
Output Con-
trol Timeout
for EtherCAT
78190000 hex
Image Log-
ging Disk
Write Error
781A0000 hex
Setting Data
Transfer Error
781B0000 hex
Output Buf-
fer Error
(EtherCAT)
88080000 hex
PLC Link
Communica-
tions Error
3-124
Meaning
Assumed cause
An error occurred in
• A serious error occurred in the
the system.
system in the Controller.
A timeout occurred
• The data output handshaking
in data output hand-
controls in the program (i.e., the
shaking control for
ON/OFF timing of the DSA sig-
measurement
nal) are not correct.
results.
• The output control timeout time
is too short in comparison with
the program processing time.
• The parallel I/O DSA or GATE
signal is not wired correctly.
A timeout occurred
• The data output handshaking
in data output hand-
controls in the program (i.e., the
shaking control for
ON/OFF timing of the Result
measurement
Set Request signal) are not cor-
results.
rect.
• The output control timeout time
is too short in comparison with
the program processing time.
Writing data to the
• A logging disk is not inserted.
image logging disk
• The available space on the log-
failed.
ging disk is not sufficient.
• There is no logging folder.
• Security restrictions are set on
the logging disk.
An error occurred
• Scene data was edited when
while transferring
there was little available space
the scene data.
on the RAM disk and the opera-
tion mode was Single- line
High-speed Mode.
• The data transfer button was
clicked when there was little
available space on the RAM
disk and the operation mode
was Non-stop Adjustment
Mode.
The data output
• Data measurements are being
buffer for measure-
performed on a period that is
ment data is full.
shorter than the time that is
required for data output hand-
shake controls in the program.
A PLC Link cannot
• There is a mistake in the PLC
be established.
or Vision Sensor communica-
tions settings.
• The Ethernet or RS-232C cable
is damaged.
Level
Maj
Prt
Min
Obs Info
S
FH/FZ5 Vision
System
FH/FZ5 Series
User's Manual
for Communi-
cations Set-
tings (Z342)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
NJ-series Troubleshooting Manual (W503)
Reference

Advertisement

Table of Contents
loading

Table of Contents