Omron NJ Series Troubleshooting Manual page 135

Sysmac machine automation controller
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

Event code
Event name
57290000 hex
Track Option
(Ver. 1.06)
Structure ON
Compensa-
tion Setting
Out of Range
572A0000 hex
Track Option
(Ver. 1.06)
Structure
OFF Com-
pensation
Setting Out of
Range
572B0000 hex
Number of
(Ver. 1.06)
Array Ele-
ments in
Switch Struc-
ture Variable
Out of Range
572C0000 hex
Number of
(Ver. 1.06)
Array Ele-
ments in Out-
put Signal
Structure
Variable Out
of Range
572D0000 hex
Number of
(Ver. 1.06)
Array Ele-
ments in
Track Option
Structure
Variable Out
of Range
572E0000 hex
Numbers of
(Ver. 1.06)
Elements in
Output Sig-
nals and
Track Option
Arrays Not
Matched
57310000 hex
Same Track
(Ver. 1.06)
Number Set-
ting in Switch
Structure Out
of Range
NJ-series Troubleshooting Manual (W503)
Meaning
Assumed cause
The value of
• The value of the member of the
OnCompensation
structure variable that was
that is specified in
specified for the in-out variable
the TrackOptions in-
of the instruction is out of
out variable to a
range.
motion control
instruction is out of
range.
The value of Off-
• The value of the member of the
Compensation that
structure variable that was
is specified in the
specified for the in-out variable
TrackOptions in-out
of the instruction is out of
variable to a motion
range.
control instruction is
out of range.
The number of ele-
• The number of elements in an
ments in an array in
array of the structure variable
the structure vari-
that was specified for the in-out
able that is speci-
variable of the instruction is out
fied in the Switches
of range.
in-out variable to a
motion control
instruction is out of
range.
The number of ele-
• The number of elements in an
ments in an array in
array of the structure variable
the structure vari-
that was specified for the in-out
able that is speci-
variable of the instruction is out
fied in the Outputs
of range.
in-out variable to a
motion control
instruction is out of
range.
The number of ele-
• The number of elements in an
ments in an array in
array of the structure variable
the structure vari-
that was specified for the in-out
able that is speci-
variable of the instruction is out
fied in the
of range.
TrackOptions in-out
variable to a motion
control instruction is
out of range.
The arrays in the
• The arrays in the output signal
structure variables
structure variable and track
that are specified
option structure variable that
for the Outputs and
are specified for the in-out vari-
TrackOptions in-out
ables to the instruction do not
variables to a
have the same number of ele-
motion control
ments.
instruction do not
have the same
number of ele-
ments.
The same track
• The same track number was
number was speci-
specified more than the allow-
fied more than the
able number of times for the
allowable number of
TrackNumber in the Switches
times for the Track-
in-out variable to a motion con-
Number in the
trol instruction.
Switches in-out
variable to a motion
control instruction.
3 Error Tables
Level
Maj
Prt
Min
Obs
Info
S
NJ-series
Motion Con-
trol Instruc-
tions
Reference
Manual (Cat.
No. W508)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
Reference
3
3-73