Event code
Event name
04BA0000 hex
Connection
Error
between
Inverter and
Communica-
tions Unit
04BB 0000 hex
Inverter
Warning
04BC0000 hex Inverter Trip
34F0 0000 hex
PDO Setting
Error
FH-series Vision Systems
Event code
Event name
08210000 hex
Fan/Power
Supply Error
08220000 hex
Camera
Overcurrent
Detected
08230000 hex
Parallel I/O
Overcurrent
Detected
182D0000 hex Setting Data
Load Error
38590000 hex
Camera Con-
nection Error
385A 0000 hex
Change in
Connected
Camera
NJ-series Troubleshooting Manual (W503)
Meaning
Assumed cause
An error occurred in
• Contact failure between the
the connection
Inverter and the EtherCAT
between the
Communications Unit for the
Inverter and the
Inverter.
EtherCAT Commu-
• Inverter trip was reset.
nications Unit for
• The Inverter was initialized or
the Inverter.
the mode was changed.
• The EtherCAT Communications
Unit for the Inverter failed.
An Inverter warn-
• An Inverter warning was
ing was detected.
detected.
An Inverter trip was
• An Inverter trip was detected.
detected.
There is an illegal
• The PDO mapping or Sync-
setting value in the
Manager settings are incorrect.
PDO mapping.
Meaning
Assumed cause
An error occurred in
• A foreign object is interfering
the fan or power
with fan operation.
supply.
• A suitable power supply voltage
is not being used, resulting in
an overvoltage or undervoltage.
An overcurrent
• There is a short circuit inside
flowed to the Cam-
the Camera cable or in a circuit
era.
inside the Controller.
An overcurrent
• A parallel I/O interface line is
occurred in the par-
short-circuited.
allel I/O interface.
Loading the scene
• The data is corrupted because
group data failed.
the power supply was turned
OFF while saving the previous
scene data.
• As the result of changing the
operation mode, the required
amount of memory increased,
resulting in insufficient memory.
The Camera con-
• A Camera is not connected to
nection is wrong.
the Controller.
• The Camera cable is broken.
• The Camera Selection settings
are not correct in the Camera
Image Input and Camera
Switching processing items.
• A Camera is not connected to
the Camera port on the Control-
ler according to the Camera
Selection settings in the Cam-
era Image Input and Camera
Switching processing items.
The Camera that is
• The Camera connection infor-
connected is differ-
mation in the scene data does
ent from when data
not agree with the connection
was last saved.
information for the Camera con-
nected to the Controller.
3 Error Tables
Level
Maj
Prt
Min
Obs
Info
S
MX2/RX
Series Inverter
EtherCAT
Communica-
tion Unit
User's Manual
(Cat. No. I574)
S
Same as
above.
S
Same as
above.
S
Same as
above.
Level
Maj
Prt
Min
Obs
Info
S
FH/FZ5 Vision
System
FH/FZ5 Series
User's Manual
for Communi-
cations Set-
tings (Z342)
S
Same as
above.
S
Same as
above.
Same as
above.
S
Same as
above.
S
Same as
above.
Reference
3
Reference
3-123

Advertisement