Output Protection Functional Block; U25 Id/Status Register Bit Description (Read @ $D0X01) - Fluke 9100 Series Service Manual

Vector output i/o module
Hide thumbs Also See for 9100 Series:
Table of Contents

Advertisement

Table 2-10.
___________________________________________________________________________
BIT
___________________________________________________________________________
3
2
1,0
___________________________________________________________________________

Output Protection Functional Block

The vector data on the OUT-BUS of the Top PCA is connected to diode
packs (BAV99) that are connected to +5 volts and ground to clamp
overvoltage and undervoltage on the outputs. The output connectors (J1
and J2) have 33 ohm resistors in series with the output that provide
high speed serial termination as well as allowing current limiting in
cases of overvoltage, undervoltage, or stuck outputs.

U25 ID/Status Register Bit Description (Read @ $D0X01)

SIGNAL
DONE
Not Done
HS-ENABLE
Not Suspended
ID CODE = 01
1
2-29
2/Theory of Operation
0
Done
Suspended