Sign In
Upload
Manuals
Brands
Fluke Manuals
I/O Systems
2638A
Fluke 2638A Manuals
Manuals and User Guides for Fluke 2638A. We have
3
Fluke 2638A manuals available for free PDF download: User Manual, Remote Programmers Manual, Calibration Manual
Fluke 2638A User Manual (103 pages)
HYDRA Series III Data Acquisition Unit
Brand:
Fluke
| Category:
Data Loggers
| Size: 9.2 MB
Table of Contents
Table of Contents
3
1 Product Overview and Specifications
9
Introduction
9
Product Overview
9
Front and Rear-Panel Overview
11
Safety Information
15
Screen Capture Feature
17
About this Manual
18
The Product Manual Set
18
General Specifications
19
Measurement Specifications
21
DC Voltage
21
DC Voltage Input Characteristics
21
DC Voltage Accuracy
21
DC Voltage Additional Errors
22
AC Voltage
22
AC Voltage Input Characteristics
22
AC Voltage Accuracy
23
Additional Low Frequency Errors
23
DC Current
23
DC Current Input Characteristics
23
DC Current Accuracy
24
DC Current Additional Errors
24
AC Current
24
AC Current Input Characteristics
24
AC Current Accuracy
25
Additional Low Frequency Errors
25
Frequency
25
Frequency Accuracy
25
Resistance
25
Resistance Input Characteristics
26
Resistance Accuracy
26
Resistance Additional Errors
26
Rtd
26
RTD Temperature Accuracy
27
RTD Measurement Characteristics
27
Thermistor
27
Thermistor Temperature Accuracy
27
Thermistor Measurement Characteristics
28
Thermocouple
28
Thermocouple Temperature Accuracy
28
Thermocouple Measurement Characteristics
29
Digital I/O
29
Totalizer
29
Trigger
30
Alarm Output
30
2638A-100 Universal Input Module
30
General
30
2 Initial Setup and Configuration
31
Introduction
31
Set the Regional Voltage
31
Fuse Replacement and Line-Voltage Selection
32
Connect to Mains Power
33
Set the Handle Position
34
Power on and Standby
35
Warm-Up the Product
36
Configure the Product
36
Input Module and Relay Card Installation
37
Module Indicator Example
38
Relay Card Installation
39
Set up Security
40
3 Input and Channel Configuration
41
Introduction
41
Input Wiring
41
The Universal Input Module
41
Wiring Safety and Considerations
42
3-Wire and 4-Wire Sense Input Configuration
43
Wire and 4-Wire Channel Reservation
44
Input Types and Wiring Diagrams
45
Input Wiring Instructions
46
Channel Configuration
47
About Channel Numbers
47
Channel Types and Numbers
48
Example Channel Assignment
49
Basic Channel Operations
50
Open the Channel Setup Menu
50
Set Channels to on or off
51
Verify a Channel
52
Zero a Channel
52
Copy a Channel
53
Save or Load a Channel Configuration (Setup File)
54
Reset the Channel and Test Configuration
56
Analog Channel Configuration (Ch001, Ch101 to Ch322)
56
Current and Voltage Channels
57
Resistance Channels
58
Thermocouple Channels
59
Frequency Channels
60
Thermistor Channels
61
PRT Channels
62
Digital I/O (DIO) Channel Configuration (Ch401)
63
Totalizer Channel Configuration (Ch402)
64
Read Mode
64
Debounce
64
Totalizer Channel Configuration
65
Math Channel Configuration (Ch501 to Ch520)
66
Math Channel Configuration
68
MX+B, Alarms, and Channel Options
69
MX+B Scaling
69
HI and lo Channel Alarms
70
Rear-Panel Alarm Outputs
71
Channel Delay
72
Rate of Change
72
Nplc
73
Input Impedance
73
Bandwidth
73
Display as
73
Open Detect
73
4 Scan/Monitor, Record, and Data
74
Introduction
74
Scan
74
The Scan Menu
75
About Scan Timing and Sampling
76
Settling Time Delay Values
77
Configure a Scan
78
Trigger Type
79
Auto Recording
80
File Destination
80
Sample Rate
80
Data Security
81
Temperature Unit
82
Align Channels
82
Automatic Power Loss Scan Resume
83
Basic Scan Procedures
83
Start a Scan
83
View Scan Data and Statistics
84
Graph the Measurements
85
Monitor
86
Record
87
Record Measurement Data
87
Memory Consumption for Recorded Data
88
Open and View Measurement Data on a PC
88
Scan Data File Name Convention
89
How to Read the Setup CSV File
90
How to Read the Data CSV File
92
5 DMM Operation
93
Introduction
93
About the DMM Function
93
Input Type Selection and Range Adjustment
94
More Functions (PT385 or PT392)
94
Relative Measurements
94
Graph the Measurements
95
Measurement Statistics
96
6 Maintenance and Care
97
Introduction
97
Clean the Product
97
Replace the Fuse
97
Memory Reset and Factory Reset
98
Firmware Update
99
User-Replaceable Parts and Accessories
101
Error Messages and Troubleshooting
102
Troubleshooting
103
Advertisement
Fluke 2638A Calibration Manual (60 pages)
HYDRA Series
Brand:
Fluke
| Category:
I/O Systems
| Size: 2.53 MB
Table of Contents
Table of Contents
3
Introduction
9
Contact Fluke
9
Safety Information
10
General Specifications
13
Measurement Specifications
14
DC Voltage
14
DC Voltage Input Characteristics
14
DC Voltage Accuracy
15
DC Voltage Additional Errors
15
AC Voltage
15
AC Voltage Input Characteristics
16
AC Voltage Accuracy
16
Additional Low Frequency Errors
16
DC Current
16
DC Current Input Characteristics
17
DC Current Accuracy
17
DC Current Additional Errors
17
AC Current
17
AC Current Input Characteristics
17
AC Current Accuracy
18
Additional Low Frequency Errors
18
Frequency
18
Resistance
18
Resistance Input Characteristics
19
Resistance Accuracy
19
Resistance Additional Errors
19
Rtd
19
RTD Temperature Accuracy
20
RTD Measurement Characteristics
20
Thermistor
20
Thermistor Temperature Accuracy
20
Thermistor Measurement Characteristics
21
Thermocouple
21
Thermocouple Temperature Accuracy
21
Thermocouple Measurement Characteristics
22
Digital I/O
22
Totalizer
22
Trigger
23
Alarm Output
23
2638A-100 Universal Input Module
23
General Maintenance
24
If the Product Does Not Turn on
24
Clean the Product
24
Replace the Line Power Fuse
24
Battery Replacement
25
Memory and Factory Reset
26
Required Equipment
27
Test Considerations
29
Performance Tests
29
Front Panel Test
30
DC Volts Verification
30
DC Volts Verification Steps
31
Volts AC and Frequency Verification
32
AC Volts Verification Steps
33
4-Wire Ohms Verification
34
PRT Verification Steps
35
Configure Resistance Display
35
Thermistor Verification Steps
36
Configure Resistance Display
36
DC Current Verification
37
DC Current Verification Steps
38
AC Current Verification Steps
39
2638A-100 Module Verification
40
Calibration Adjustment
41
Unlock the Product
41
Unlock the Product with a Remote Interface
41
Reset the Admin Password
42
Disassembly
43
Change the Calibration Date Remotely
45
Mainframe" Adjustment Process
45
Remote Commands for Calibration
51
Remote Programming Examples
52
Start a Full Calibration
52
Calibrate 1 V DC Range Only
53
Write Calibration Date to a Module
53
Command References
54
User-Replaceable Parts and Accessories
59
Fluke 2638A Remote Programmers Manual (96 pages)
Data Acquisition Unit
Brand:
Fluke
| Category:
Industrial Electrical
| Size: 0.93 MB
Table of Contents
Table of Contents
3
Introduction
5
How to Contact Fluke
5
Remote Operation Commands
6
System Status Diagram
7
List of Commands
8
Remote Programming Examples
17
Single Channel, One-Shot
17
One-Shot Scan
18
Single Channel, Continuous
18
Continuous Scanning
19
Number of Scan Sweeps
20
Full-Speed Sampling
21
Scanning with Scan Interval
21
External Trigger
22
Monitoring
23
Alarm Trigger
24
Alphabetical List of Serial Commands
25
Advertisement
Advertisement
Related Products
Fluke 2635A
Fluke 2620A
Fluke 2680A
Fluke 268XA
Fluke 26
Fluke 26500090
Fluke 26500000
Fluke 26500610
Fluke 26501100
Fluke 26501200
Fluke Categories
Measuring Instruments
Test Equipment
Multimeter
Thermometer
Laboratory Equipment
More Fluke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL