Operating the unit

5.6.15 QualityControlUsing

INFORMATION
INFORMATION
Requirements Equipment function menu open
60
5. Save the cooking program.
Rest stage is saved in the cooking program.
QualityControl is a cooking time optimisation function, which adjusts the tem-
perature automatically. It optimises the preheating process.
It is switched on as standard and can be switched off for individual programs.
The particular setting applies to all cooking programs until it is changed.
a
Image: QualityControl selection window
a QualityControl field
1. Tap the Settings field.
2. Enter PIN 111 and confirm.
The QualityControl field is displayed.
3. Switch the function on or off as required.
4. Tap the QualityControl field.
The "ON" display changes automatically to "OFF" or vice
versa.
The QualityControl function is set.