Handling Messages and Error Messages
[TEMPERATURE IS TOO LOW **°C]
The temperature of the location where the machine is installed has fallen below the ambient
temperature at which the machine can operate.
Operation cannot be continued. Turn off the sub power. The displayed temperature is the current ambient tem-
perature of the installation location. Bring the installed location to a temperature at which operation is possible
(20 to 32°C or 68 to 90°F) and allow the machine to come to room temperature, and then turn on the power.
[DATA ERROR CANCELING...]
Printing was stopped because a problem was found in the received data.
Operation cannot be continued. Check whether there is an error in the data. Check for a problem with the
connector cable or the computer, and then redo the operations starting from the setup of the media.
[WRONG CARTRIDGE]
A cartridge that cannot be used was installed
Remove the ink cartridge to clear the error. Use an ink cartridge of the specified type.
[WRONG HEAD IS INSTALLED]
An unusable print head has been installed.
Turn off the sub power. After you switch off the power, contact your authorized Roland DG Corp. dealer.
[AVOIDING DRY-UP TURN POWER OFF]
The print heads were forced to the home position to prevent them from drying out.
Operation cannot be continued. Switch the sub power off, then back on. Opening the front cover while printing
is in progress causes an emergency stop. Never allow the print heads to remain in this state.
[MOTOR ERROR TURN POWER OFF]
A motor error occurred.
Operation cannot be continued. Turn off the sub power. Next, eliminate the cause of the error, and then im-
mediately switch on the sub power. If the machine is left with the error uncorrected, the print heads may dry
out and become damaged. This error may be caused by the media being set incorrectly.