l Keep Alive
Setting
Keep Alive
Keep Alive monitoring
time
Linger option
l Default Gateway
Setting
Default gateway
*1.
When the IP address setting method is set to Obtain from BOOTP server or Fix at the IP address
obtained from BOOTP server, the default gateway obtained from a BOOTP server is enabled.
*2.
Even if you are using both of port 1 and port 2, you can only set the default gateway for one of the ports.
l IP Router Table
Setting
Destination IP Address
Destination Mask IP Ad-
dress
Gateway Address
A - 4
For each connection number, set whether to use the Keep Alive
function to check if the connected client nodes, such as FTP
server functions, Sysmac Studio, TCP/UDP message service
(TCP only), are communicating.
If the Keep Alive function is set to Use, and a remote node does
not respond during the monitoring time set in the Keep Alive
monitoring time setting, the connection to the remote node is
disconnected.
The connection to a remote node is left open if the power supply
to the remote node is turned OFF without warning. Use the Keep
Alive function whenever possible.
Use
Do not use
If the Keep Alive function is set to Use, and a remote node does
not respond during the monitoring time set in the Keep Alive
monitoring time setting, the connection to the remote node is
disconnected.
Setting range: 1 to 65,535 [sec]
Set whether to specify the Linger Option when you connect to
the TCP/UDP message service (TCP only).
If the Linger Option is specified, the port number is immediately
opened even before the port number is released after the TCP
connection closes (approx. one minute).
Specify
Do not specify
Set the IP address of the default gateway for the built-in Ether-
*1
*2
Net/IP port.
This setting is not required when the default gateway is not used.
Set these settings when the built-in EtherNet/IP port is used for
tag data links or CIP message communications with nodes on
other IP network segments via an IP router. Accordingly, set
these settings when you use a Communication Control Unit as
an IP router using the IP routing function for the built-in
EtherNet/IP port.
You can set up to 64 combinations of IP addresses and gateway
addresses.
Specify 0 for the host portions of the IP addresses.
NX-series Communication Control Unit Built-in Function User's Manual (Z396)
Description
Description
Description
Default
Use
300
Do not specify
Default
None
Default
None
None