Omron NX-series User Manual page 130

Safety network controller communication control unit built-in function
Hide thumbs Also See for NX-series:
Table of Contents

Advertisement

8 CIP Message Communications
Attribute
Parameter name
ID
05 hex
Media Counters
Alignment Errors
FCS Errors
Single Collisions
Multiple Collisions
SQE Test Errors
Deferred Transmissions
Late Collisions
Excessive Collisions
MAC Transmit Errors
Carrier Sense Errors
Frame Too Long
MAC Receive Errors
06 hex
Interface Control
Control Bits
Forced Interface Speed
8 - 34
Description
Media counters for the com-
munications port.
Number of frames received
that were not octets in length.
Number of frames received
that did not pass the FCS
check.
Number of frames sent suc-
cessfully with only one colli-
sion.
Number of frames sent suc-
cessfully with two or more
collisions.
Number of times a SQE test
error message was generat-
ed.
The number of frames for
which the first attempt to send
was delayed because the me-
dia was busy.
The number of collisions de-
tected in packets that were
sent after 512 bit times.
The number of frames that
failed to be sent because of
excessive collisions.
The number of frames that
failed to be sent due to an in-
ternal MAC sublayer trans-
mission error.
The number of times the car-
rier sense conditions were
lost or the number of times an
assertion failure occurred
when an attempt was made
to send the frame.
The number of frames re-
ceived that exceeded the
maximum allowed frame size.
The number of frames that
could not be received through
the interface due to an inter-
nal MAC sublayer reception
error.
Control settings for the inter-
face.
Specify Auto Nego and full
duplex for Ethernet communi-
cations.
Gives the set value of the
Ethernet baud rate.
NX-series Communication Control Unit Built-in Function User's Manual (Z396)
Write/Read data
Attrib-
ute
Data type
Read
Struct
---
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
UDINT
Reads the current val-
ue.
Write
Struct
---
WORD
Refer to (b) Control
Bits Details, below.
UINT
Reads the setting val-
ue.
Value

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-csg series

Table of Contents