Omron NX-series User Manual page 126

Safety network controller communication control unit built-in function
Hide thumbs Also See for NX-series:
Table of Contents

Advertisement

8 CIP Message Communications
Attrib-
Parameter name
ute ID
02 hex
Configuration Capabili-
ty
03 hex
Configuration Control
04 hex
Physical Link Object
Path size
Path
05 hex
Interface Configuration
IP Address
Network Mask
Gateway Address
Name Server
Name Server2
Domain Name
06 hex
Host Name
Request Paths to Specify Objects
When you specify an object, specify the request path for each service code as given below.
Service code
01 hex
Get_Attribute_All
0E hex
Get_Attribute_Single
10 hex
Set_Attribute_Single
8 - 30
Description
Indicates the Controller Con-
figurations and Setup that can
be set to the interface.
Sets the method used to set
the IP address when the inter-
face starts.
The path to the link object in
the physical layer
The path size (WORD size).
The path to the link object in
the physical layer (static).
The interface settings
IP address
Subnet mask
Default gateway
Primary name server
Secondary name server
Domain name
Host name (reserved)
Class
Instance ID
ID
F5 hex
Specifying a service for a
class: 00 hex
Specifying a service for an in-
stance: 01 hex
NX-series Communication Control Unit Built-in Function User's Manual (Z396)
At-
Write/Read data
trib-
Data type
ute
Read
DWORD
bit 0: BOOTP Client: Always
TRUE
bit 1: DNS Client: Always
TRUE
bit 2: DHCP Client: Always
FALSE
bit 3: DHCP - DNS Update: Al-
ways FALSE
bit 4: Configuration Settable:
Always TRUE
bit 5: Hardware Configurable:
Always FALSE
bit 6: Interface Configuration
Change Requires Reset: Al-
ways FALSE
bit 7: ACD Capable: Always
TRUE
bit 8 to 31: Reserved (always
FALSE)
Write
DWORD
bit 0: Static IP address
bit 1: Set by BOOTP
Read
Struct
---
UINT
0002 hex
EPATH
20 F6 24 01 hex
Write
Struct
---
UDINT
Set value
UDINT
Set value
UDINT
Set value
UDINT
Set value
UDINT
Set value
STRING
Set value
Write
STRING
Always 0000 hex
Not required
Reading a class attribute: 01
to 03 hex
Reading and writing an in-
stance attribute: 01 to 06 hex
Value
Attribute ID

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-csg series

Table of Contents