MODBUS COM Config

This tab provides the detail information about the Modbus communication parameters.
User can read and write the Device Address, Turn Around Delay, Baud Rate, Parity using
this tab.
Refer the below table for modbus configuration parameter.
Key: Plain = Read only Bold = Configurable Bold underline = Method Bold italic = Table or graph
Device Address
Turnaround Delay
Baud Rate
Parity
Revision 1.0
MODBUS Configuration Parameters
Slave device address range
is 1 to 247
Turn around delay range is
1 to 200 ms
Available baud
rate:
1200, 2400, 4800, 9600,
19200
Available Parity selection:
even, odd, none
SMV800 Modbus User's Guide
The device address field can be used to
configure the device address.
The Turnaround Delay time (ms) field can
be used to configure the device's
turnaround delay time, it is the amount of
time that the device takes to respond to a
Modbus request
The baud rate is user selectable
under Modbus com config tab.
Default baud rate is 9600
The parity field can be used to
configure parity type.
Page 67