Density
Manual Input Density
Density Coefficient_d#
Lower TempLimit Density
TpMin
Upper TempLimit Density
TpMax
Revision 1.0
ON/OFF
#.#
SMV800 Modbus User's Guide
When Algorithm Option = Advanced
Algorithms
Fluid Type = Liquid
When Algorithm Option = SMV3000 /ASME
1989 with Dynamic Corrections or Standard
Fluid Type = Liquid
Equation Model = Dynamic or Standard
Minimum Temperature to select the initial
Temperature vs Density value in the
polynomial equation for auto calculation of
Density. Enter the temperature value in the
selected unit in the Unit Configuration
screen.
Maximum Temperature to select the end
point Temperature vs Density value in the
polynomial equation for auto calculation of
Density. Enter the temperature value in the
selected unit in the Unit Configuration
screen.