4.15 Humidity Sensor System Abnormality

CC
Error Code
Applicable
FCQ
Models
Method of Error
The error is detected according to the humidity (output voltage) detected by humidity sensor.
Detection
Error Decision
The error is generated when the humidity sensor becomes disconnected or shorted when the
Conditions
unit is running.
Error code is displayed but the system operates continuously.
 Defective sensor
Supposed
 Broken wire
Causes
 External factor (Noise, etc.)
Troubleshooting
Caution
Be sure to turn off the power switch before connecting or disconnecting connectors, or parts may be damaged.
Remove the humidity sensor from the
indoor unit PCB and insert it again.
Delete the error code record from the
remote controller. (∗1)
Error is displayed again.
Note:
1. To delete the record, the ON/OFF button of the remote controller must be pressed and held for 5 seconds
in the check mode.
2. To display the code, the INSPECTION/TEST button of the remote controller must be pressed and held in
the normal mode.
CC
3. If "
" is displayed even after replacing the humidity sensor PCB (A2P) and taking the steps 1 and 2,
replace the indoor unit PCB (A1P).
105
YES
Does it function
normally?
NO
YES
(∗2)
NO
SiME281501E
It is normal.
(Poor connector contact)
Replace the humidity sensor
PCB (A2P).(∗3)
It is believed that external factors
(noise or else) other than failure
caused the error.
Service Diagnosis