Transmission Error Between Control And Inverter Pcb - Daikin RZQ Series FCQ20EVA Service Manual

Heat pump r410a 60hz
Table of Contents

Advertisement

Troubleshooting by Remote Controller

4.33 Transmission Error between Control and Inverter PCB

LC
Error Code
Applicable
RZQ45/48MYL
Models
Method of Error
Check the communication state between inverter PCB and control PCB by micro-computer.
Detection
Error Decision
When the correct communication is not conducted in certain period
Conditions
 Defective connection between the inverter PCB and control PCB
Supposed
 Defective control PCB (transmission section)
Causes
 Defective inverter PCB
 Defective noise filter
 Defective fan inverter
 Incorrect type of inverter PCB
 Defective INV. compressor
 Defective fan motor
 External factor (noise etc.)