REP 3.5 Scan Output Idler Roller
Parts List on PL 3.2
Removal
1. Remove power cord.
2. Remove document catch tray assembly
(REP 1.1).
3. Remove control panel assembly (REP 5.1).
4. Remove upper scan cover (REP 1.7).
5. Remove scan output idler roller.
a. Remove two scan idler springs from
scan output idler roller.
b. Remove two upper scan bearings
from scan output idler roller.
c. Remove scan output idler roller.
Replacement
Reinstall in reverse order.
REP 3.5, 3.6
REP 3.6 Upper Scan Assembly
Parts List on PL 3.2
Removal
1. Remove power cord.
2. Remove document catch tray assembly
(REP 1.1).
3. Remove RH cover (REP 1.2).
4. Remove coupler cover (REP 1.3).
5. Remove LH cover (REP 1.4).
6. Remove upper scan assembly.
a. Remove screw securing ground wire
to LH frame.
b. Disconnect J110 and J111 at A0 CNC
PWB.
c. Remove wire harnesses from cable
clamp.
d. Release nudger arm spring from the
scan pivot shaft.
e. Remove LH E-ring from scan pivot
shaft.
f.
Remove LH scan pivot bearing.
g. Remove scan pivot springs while
removing the scan pivot shaft.
h. Remove upper scan assembly.
12/88
4-18
www.printcopy.info
Replacement
NOTE: During reinstallation, ensure proper
alignment by:
•
Rotating upper scan assembly towards
the rear of terminal.
•
Ensuring both scan pivot springs are
properly positioned in the cutouts in the
upper scan frame and on top of the
locating tabs on the LH and RH frame
(Figure 1).
The spring coils can bind
between the upper scan frame and the
scan pivot shaft.
Reinstall in reverse order.
Telecopier 7017 / 7017SF