Table 10
System Data: 10
System Data
Bit No.
Description
Scan Registration
0
(mm)
1
2
3
Cutter Registration
4
(mm)
5
6
7
Table 11
System Data: 11
System Data
Bit No.
Description
G2 Threshold Level
0
for Modem control.
1
2
3
4
5
6
7
System Data Setup
Bit Definition
0
3210
3210
0000: (-4.0)
0110: (-1.0)
0001: (-3.5)
0111: (-0.5)
0010: (-3.0)
1000: (±0)
0011: (-2.5)
1001: (+0.5)
0100: (-2.0)
1010: (+1.0)
0101: (-1.5)
1011: (+1.5)
7654
7654
0000: (-4.0)
0110: (-1.0)
0001: (-3.5)
0111: (-0.5)
0010: (-3.0)
1000: (±0)
0011: (-2.5)
1001: (+0.5
0100: (-2.0)
1010: (+1.0)
0101: (-1.5)
1011: (+1.5)
Bit Definition
0
Examples:
Bit Numbers
76543210
Binary
Hex Code
00000000
00H
01110100
74H
11111111
FFH
www.printcopy.info
Default
1
USO
3210
0
1100: (+2.0)
1101: (+2.5)
0
1110: (+3.0)
1111: (+3.5)
0
1
7654
0
1100: (+2.0)
1101: (+2.5)
0
1110: (+3.0)
1111: (+3.5)
0
1
Default
1
USO
0
0
1
Note
0
Darkest
Default USO/RX
1
Lightest
1
1
0
8/88
6-29
RX
0
0
0
1
0
0
0
1
RX
0
0
1
0
1
1
1
0