S p e c i f i c a t i o n s a n d S p a c e
Requirements

Product Code

49K
Telecopier 7017
(USO)
59T
Telecopier 7017
(RX)

Dimensions

Height
12.5"
Width
20"
Depth
24"
Weight
46.3lbs (21kg) packed
33.0lbs (15kg) Unpacked
Minimum space requirements are needed for
normal
operator
and
service
functions. The terminal should be placed on a
sturdy, flat surface within 5 feet (1.5 metres) of
a telephone outlet and within 5 feet (1.5
metres)
of
a
grounded
electrical
Clearance should be maintained above the
unit so the covers can be opened.
terminal should not be contained within any
type of enclosure.
The terminal is considered movable if proper
telephone interface is available.

Electrical Requirements

Single phase (2 wires plus ground)
Voltage:
USO
104 to 127 VAC (nominal 115 VAC)
@ 50 Hz ± 1 Hz or 60 Hz ± 1 Hz
RX
200 to 240 VAC (nominal 220 VAC)
@ 50 Hz ± 1 Hz or 60 Hz ± 1 Hz
Telecopier 7017 / 7017SF

Power Consumption (maximum)

Operating 300 W
Standby
15 W
A standard two pole, three wire grounded
receptacle is required.

Meter Readings (USO)

Between AC Hot and Neutral 104 to 127 VAC
Between Gnd and AC Hot
Between Gnd and Neutral (longer slot) less
than 3 VAC

Meter Readings (RX)

Between AC Live and Neutral 200 to 240 VAC.

Environmental

Temperature
maintenance
Humidity
Elevation
outlet.
Heat Dissipation
The

Recording Paper

Thermal sensitive paper 100 meter roll.
www.printcopy.info
104 to 127 VAC
o
o
o
o
60
F to 90
F (15
C to 32
C)
15%
to
85%
w/o
condensation
Maximum 9,900 feet (3,000
metres) above sea level
Operating 887 BTU/hour
Standby
51 BTU/hour
6/88

Specifications and Space Requirements

6-3
Original Stacking Requirements
Originals are loaded into the ADF face down
and lead edge to the front. They are aligned
by adjusting the document guides to the
width of the originals.
Originals loaded in the ADF may be mixed in
weight and length, but should not be mixed in
width.
Weight
13 to 36 pound
(45 to 128 grams/ square meter)
Width
5.6 to 11 inches
(148 to 285 mm)
Length
4.5 to 16.5 inches (110 to 420 mm)
Note: Originals longer than 18 inches (420
mm) can be used if you select the long original
feature and manually assist the ADF feeding.
The input tray (ADF) capacity depends on the
size and weight of the paper.
Less than 32lb. originals - 30 documents
letter or 20 documents legal.
32lb. to 36lb originals - 20 documents
letter or legal.
Mixed weights - 30 documents letter if no
more than 4 originals are 32 lb. and 36 lb.
Documents
smaller
than
(220mm) will not be detected as wide
originals.
8.66