Lucent Technologies TransTalk 9000 Installation And Use Manual page 93

Digital wireless system, mdw 9031 wireless pocketphone
Hide thumbs Also See for TransTalk 9000:
Table of Contents

Advertisement

Installation Problems (continued)
Symptom
Possible Causes
Radio modules are out of
After you plug the
synchronization.
carrier into an
electrical outlet, the
PASS LED of one or
more radio modules
does not light.
A radio module is malfunc-
tioning.
The radio module was in-
A defective radio
serted without first powering
module was
replaced, and now
down the carrier. The carrier
all the handsets
is out of synchronization.
have less range
than before, and
the voice quality
has deteriorated.
When turned on,
Electrical outlets may not be
the handset
up to specifications. Electri-
display shows
cal problems, such as no
lines going on hold
ground or floating ground,
and line selections
can cause the switch to send
changing without
or receive spurious current,
any buttons being
causing problems in switch
pressed.
protocol.
* See "Customer Support" on the inside front cover of this book.
Possible Solutions
Power down the carrier, wait 15
seconds, and repower it. If you
have multiple carriers, repower
the control carrier first, and then
power the expansion carriers in
order from left to right; or use a
surge-protector strip to repower
all of the carriers at one time.)
If the problem persists, call for
help.*
1. Remove all but one radio
module from the carrier. (See
"Removing a Radio Module
from the Carrier" in Chapter 4.)
2. Test each radio module
individually, verifying that the
POWER and PASS LEDs on
each radio module light when
the carrier is powered.
3. If the PASS LED does not light,
the radio module is malfunc-
tioning. Replace the radio
module and handset.
Power down the carrier, wait 15
seconds, and repower it. If you
have multiple carriers, repower
the control carrier first, and then
power the expansion carriers in
order from left to right; or use a
surge-protector strip to repower
all of the carriers at one time.)
If the problem persists, call for
help.*
Verify that the outlets for the
communications system switch
and for the carrier(s) meet
electrical requirements. (See "AC
Outlet Check" in Chapter 2.
Troubleshooting