Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
C-3
Perform Axle Maintenance -
ANSI/CSA/AS
Axle specifi cations require that this procedure
be performed every 6 months or 6000 miles,
whichever comes fi rst.
• Brake Magnets
• Brake Controller
• Suspension Components
Required maintenance procedures and additional
axle information is available in the Dexter Axle
Operation Maintenance Service Manual
(Dexter part number LIT-001-00).
Dexter Axle Operation Maintenance Service Manual
Genie part number
3 - 20
C-4
Replace the
Hydraulic Tank Breather Cap -
Models with Optional Hydraulic Oil
The hydraulic tank is a vented-type tank. The
breather cap has an internal air fi lter that can
become clogged or, over time, can deteriorate. If
the breather cap is faulty or improperly installed,
impurities can enter the hydraulic system which
may cause component damage. Extremely dirty
conditions may require that the cap be inspected
more often.
1 Remove and discard the hydraulic tank
breather cap.
2 Install a new cap onto the tank.