5 Locate the outrigger level sensor(s) behind the
inspection door on the ground control side of
the machine.
b
a
CR66
AUTOLEVEL
RELAY
Y
X
d
a
PLATFORM
a
outrigger level sensor
b
autolevel relay (early production)
c
function manifold
d
"X" indicator
e
adjusting fastener
a
e
PLATFORM
Part No. 825934
c
FUNCTION
MANIFOLD
e
d
TONGUE
c
d
FUNCTION
MANIFOLD
X
TONGUE
Genie TZ-34/20
Section 4 • Repair Procedures
If you are not installing a new level sensor,
proceed to step 10.
6 Tag and disconnect the wire harness from the
outrigger level sensor.
7 Remove the three level sensor retaining
fasteners. Remove the level sensor from the
machine.
8 Install the new level sensor onto the machine
with the "X" on the level sensor housing located
as shown in the illustrations. Install and tighten
the level sensor retaining fasteners.
9 Connect the wire harness to the level sensor.
10 Tighten the level sensor adjusting fasteners
until the bubble in the top of the level sensor is
centered in the circles.
Note: e sure there are threads showing through
the top of the adjusting fasteners.
11 Turn the key switch to ground control.
12 Raise the outriggers until all of the outriggers
are off the ground.
13 Push and hold the yellow function enable
button. Push and hold the auto level button.
Result: The outriggers will lower and adjust to
level the machine and raise the wheels off the
ground. Use the bubble level located below the
ground controls to confi rm that the machine is
level.