January 2016
7 Add an additional 44 lbs / 20 kg of weight to
overload the platform.
Result: The platform overload indicator light
should be fl ashing at both the ground and
platform controls.
8 Test all machine functions from the platform
controls
Result: All platform control functions should not
operate.
9 Turn the key switch to ground control.
10 Test all machine functions from the ground
controls
Result: All ground control functions should not
operate.
11 Lift the test weight off the platform fl oor using a
suitable lifting device
Result: The platform overload indicator light
should turn off at both the ground and platform
controls.
Part No. 825934
Section 3 • Scheduled Maintenance Procedures
12 Test all machine functions from the ground
controls
Result: All ground control functions should
operate normally.
13 Turn the key switch to platform control.
14 Test all machine functions from the platform
controls
Result: All platform control functions should
operate.
Note: If the platform overload system is not
operating properly, refer to Repair Procedure
11-1, Calibrate the Platform Overload System (if
equipped).
Genie TZ-34/20
CHECKLIST C PROCEDURES
3 - 19